1.100X Remote Control Float Ball Valve |
|
|
|
| |
 |
|
|
|
| |
Product Specification: |
|
| |
The main valve is controlled by a float ball valve which locates on the top of tank or reservoir. The valve maintains the maximum water level
of tank or reservoir continuously.
100X diaphragm control ball valve is a multi-function hydaulic control valve, The water level can be controlled below a preset elevation,
This valve can be widely used in influent pipes of the pools and water tower in hig-rise buildings,municipal domestic water systems,
fire fighting facilites, factories and mines. When adding a solenoid valve, then comprises another type (i,e,106X), which provides
double control to water level,normally used at high overflow prevention project.Pressure Rating: PN10. PN16. PN25/Class150Size
Range: DN20mm-DN800mm (3/4" - 32") |
|
|
|
|
| |
Dimensions( mm)4. |
|
| |
DN |
L |
D |
D1 |
D2 |
Z-~d |
A1 |
A |
H1 |
H |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
50 |
240 |
165 |
165 |
165 |
125 |
125 |
125 |
102 |
102 |
99 |
4-~18 |
4-~18 |
4-~18 |
140 |
335 |
210 |
95 |
65 |
250 |
185 |
185 |
185 |
145 |
145 |
145 |
122 |
122 |
118 |
4-~18 |
4-~18 |
8-~18 |
140 |
335 |
215 |
97 |
80 |
285 |
200 |
200 |
200 |
160 |
160 |
160 |
133 |
133 |
132 |
8-~18 |
8-~18 |
8-~18 |
145 |
345 |
245 |
106 |
100 |
360 |
220 |
220 |
235 |
180 |
180 |
190 |
158 |
158 |
156 |
8-~18 |
8-~18 |
8-~18 |
155 |
365 |
305 |
152 |
125 |
400 |
250 |
250 |
270 |
210 |
210 |
220 |
184 |
184 |
184 |
8-~18 |
8-~18 |
8-~18 |
165 |
385 |
365 |
152 |
150 |
455 |
285 |
285 |
300 |
240 |
240 |
250 |
212 |
212 |
211 |
8-~18 |
8-~18 |
8-~18 |
180 |
410 |
415 |
160 |
200 |
585 |
340 |
340 |
360 |
295 |
295 |
310 |
268 |
268 |
274 |
8-~18 |
12-~18 |
12-~18 |
205 |
465 |
510 |
220 |
250 |
790 |
395 |
405 |
425 |
350 |
350 |
370 |
320 |
320 |
330 |
12-~18 |
12-~18 |
12-~18 |
225 |
505 |
560 |
250 |
300 |
900 |
445 |
460 |
485 |
400 |
400 |
430 |
370 |
370 |
389 |
12-~18 |
12-~18 |
16-~18 |
245 |
545 |
658 |
372 |
400 |
960 |
565 |
580 |
620 |
515 |
525 |
550 |
482 |
482 |
503 |
16-~18 |
16-~18 |
16-~18 |
285 |
625 |
735 |
415 |
|
|
|
|
| |
Main Technical Features |
|
| |
PN |
1.0MPa |
1.6MPa |
2.5MPa |
Shell Test |
1.5MPa |
2.4MPa |
3.75MPa |
Seal Test |
1.1MPa |
1.76MPa |
2.75MPa |
Suitable Temperature |
¡¶80oC |
Suitable Medium |
Water |
|
|
| |
|
| |
2.200X Pressure Reducing Valve |
|
| |
 |
|
| |
Product Specification: |
|
| |
The valve maintains a preset downstream pressure, regardless of upstream pressure or flow fluctuation. The main valve is controlled by
a pilot valve, which makes the main valve modulating to maintain the downstream pressure.
The 200X pressure reducing valve is an intelligent valve that uses the self energy of the medium to regulate and control the pressure
in pipes. The 200X pressure reducing valve can be used in domestic water supply, fire fighting water supply and other industrial water supply systems. The outlet pressure of the main valve can be regulated through the adjustment of the pressure reducing valve;
the outlet pressure does not vary along with the inlet pressure and inlet flow. Accordingly, the outlet pressure can be safely and
reliably maintained at a preset value and the preset value can be adjusted according to actual needs to obtain your pressure reducing
goal.
This valve is precise in pressure reduction, stable in performance, safe, reliable, easy, and convenient to install and adjust and
offers a long service life. Pressure Rating: PN10. PN16. PN25/Class150Size Range: DN20mm-DN800mm (3/4" - 32") Test
and inspection: GB/T 13927 API598 |
|
| |
Dimensions( mm) |
|
| |
DN |
L |
D |
D1 |
D2 |
Z-~d |
F1 |
F |
H1 |
H |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
50 |
203 |
165 |
165 |
165 |
125 |
125 |
125 |
102 |
102 |
99 |
4-~18 |
4-~18 |
4-~18 |
155 |
330 |
278 |
88 |
65 |
216 |
185 |
185 |
185 |
145 |
145 |
145 |
122 |
122 |
118 |
4-~18 |
4-~18 |
8-~18 |
165 |
350 |
298 |
97 |
80 |
241 |
200 |
200 |
200 |
160 |
160 |
160 |
133 |
133 |
132 |
8-~18 |
8-~18 |
8-~18 |
175 |
365 |
313 |
105 |
100 |
292 |
220 |
220 |
235 |
180 |
180 |
190 |
158 |
158 |
156 |
8-~18 |
8-~18 |
8-~18 |
195 |
410 |
250 |
120 |
125 |
330 |
250 |
250 |
270 |
210 |
210 |
220 |
184 |
184 |
184 |
8-~18 |
8-~18 |
8-~18 |
220 |
455 |
365 |
135 |
150 |
356 |
285 |
285 |
300 |
240 |
240 |
250 |
212 |
212 |
211 |
8-~18 |
8-~18 |
8-~18 |
230 |
475 |
385 |
160 |
200 |
495 |
340 |
340 |
360 |
295 |
295 |
310 |
268 |
268 |
274 |
8-~18 |
12-~18 |
12-~18 |
255 |
530 |
505 |
190 |
250 |
622 |
395 |
405 |
425 |
350 |
355 |
370 |
320 |
320 |
330 |
12-~18 |
12-~18 |
12-~18 |
300 |
623 |
590 |
240 |
300 |
698 |
445 |
460 |
485 |
400 |
410 |
430 |
370 |
370 |
389 |
12-~18 |
12-~18 |
12-~18 |
340 |
700 |
620 |
270 |
350 |
787 |
505 |
520 |
555 |
460 |
470 |
490 |
430 |
430 |
448 |
16-~18 |
16-~18 |
16-~18 |
415 |
840 |
677 |
300 |
400 |
914 |
565 |
580 |
620 |
515 |
525 |
550 |
482 |
482 |
503 |
16-~18 |
16-~18 |
16-~18 |
430 |
880 |
690 |
335 |
450 |
978 |
615 |
640 |
670 |
565 |
585 |
600 |
532 |
545 |
548 |
20-~18 |
20-~18 |
20-~18 |
430 |
880 |
715 |
360 |
|
| |
Main Technical Features |
|
| |
PN |
1.0MPa |
1.6MPa |
2.5MPa |
Shell Test |
1.5MPa |
2.4MPa |
3.75MPa |
Seal Test |
1.1MPa |
1.76MPa |
2.75MPa |
Suitable Temperature |
¡¶80oC |
Suitable Medium |
Water |
|
| |
3. 300X Flow Control Check Valve |
|
| |
 |
|
| |
Product Specification: |
|
| |
The valve is used at outlet pipe of pump, with its open & close speed adjustable, and also used at high building for reducing water
hammer & water slamming.
The 300X slow shut-off check valve is an intelligent valve intended for installation in the pump outlet of a high-rise buildings' water
supply system. When uses it effectively prevents the reverse flow of a medium, as well as water hammer-type phenomena. This valve utilizes a motorized valve, check valve and water hammer eliminator at the same time and can effectively increase the safety and
reliabilityof a water supply system.It integrates such functions as slow opening, fast and slow closing in order to eliminate water hammer,
so asto prevent the occurrence of pump-on water hammer and pump-off water hammer. The valve can automatically realize turning
on/
off according to the operation specification of the pump.By pressing the On/Off button of the pump motor; a large flow and small pressure loss can be achieved. Our slow shut-off check valve are suitable for use with pipes of 600 caliber and below.
Pressure Rating: PN10. PN16. PN25/Class150Size Range: DN20mm-DN800mm (3/4" - 32")Test and inspection: GB/T 13927 API598 |
|
| |
Dimensions( mm) |
|
| |
DN |
L |
D |
D1 |
D2 |
Z-~d |
A1 |
A |
H1 |
H |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
50 |
240 |
165 |
165 |
165 |
125 |
125 |
125 |
102 |
102 |
99 |
4-~18 |
4-~18 |
4-~18 |
210 |
320 |
137 |
95 |
65 |
250 |
185 |
185 |
185 |
145 |
145 |
145 |
122 |
122 |
118 |
4-~18 |
4-~18 |
8-~18 |
215 |
330 |
145 |
97 |
80 |
285 |
200 |
200 |
200 |
160 |
160 |
160 |
133 |
133 |
132 |
8-~18 |
8-~18 |
8-~18 |
220 |
330 |
178 |
109 |
100 |
360 |
220 |
220 |
235 |
180 |
180 |
190 |
158 |
158 |
156 |
8-~18 |
8-~18 |
8-~18 |
230 |
410 |
232 |
152 |
125 |
400 |
250 |
250 |
270 |
210 |
210 |
220 |
184 |
184 |
184 |
8-~18 |
8-~18 |
8-~18 |
245 |
480 |
286 |
152 |
150 |
455 |
285 |
285 |
300 |
240 |
240 |
250 |
212 |
212 |
211 |
8-~18 |
8-~18 |
8-~18 |
260 |
420 |
318 |
160 |
200 |
585 |
340 |
340 |
360 |
295 |
295 |
310 |
268 |
268 |
274 |
8-~18 |
12-~18 |
12-~18 |
280 |
430 |
413 |
220 |
250 |
790 |
395 |
405 |
425 |
350 |
355 |
370 |
320 |
320 |
330 |
12-~18 |
12-~18 |
12-~18 |
300 |
450 |
502 |
250 |
300 |
900 |
445 |
460 |
485 |
400 |
410 |
430 |
370 |
370 |
389 |
12-~18 |
12-~18 |
12-~30 |
320 |
460 |
600 |
372 |
400 |
960 |
565 |
580 |
620 |
515 |
525 |
550 |
482 |
482 |
503 |
16-~26 |
16-~30 |
16-~36 |
360 |
480 |
677 |
415 |
|
| |
Main Technical Features |
|
| |
PN |
1.0MPa |
1.6MPa |
2.5MPa |
Shell Test |
1.5MPa |
2.4MPa |
3.75MPa |
Seal Test |
1.1MPa |
1.76MPa |
2.75MPa |
Suitable Temperature |
¡¶80oC |
Suitable Medium |
Water |
|
| |
4.400X Flow control valve |
|
| |
 |
|
| |
Product Specification: |
|
| |
The valve limits the flow rate in the pipeline to a preset rate, regardless of upstream pressure variations. The valve is controlled by pilot valve, which takes use of integrated orifice plate to detect flow rate represented by differential pressure, and the differential pressure is
used to control the pilot valve to implement flow rate control.
The 400X flow control valve is a multifunctional valve that adopts the mode of flow control employed by high-precision pilot valve. It
is suitable for use in water distribution pipes within which the flow and pressure need to be controlled, and can serve to keep the
preset flow constant, restrict excessive flow at a preset value and reduce the excessively high pressure upstream properly. This valve
differs from other conventional throttle valve, which normally work through reducing the flow area by means of orifice plates or purely
mechanically,by making use of an appropriate pilot valve to minimize the loss of energy in the course of flow regulation. The 400X flow control valve can completely stop the flow in case of an emergency to avoid loss. Accordingly, it boasts high control sensitivity and is
reliable, safe,simple to debug and offers a long service life. Pressure Rating: PN10. PN16. PN25/Class150Size Range:
DN20mm-DN800mm (3/4" - 32")Test and inspection: GB/T 13927 API598 |
|
| |
Dimensions( mm) |
|
| |
DN |
L |
D |
D1 |
D2 |
Z-~d |
H1 |
H |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
PN10 |
PN16 |
PN25 |
50 |
203 |
165 |
165 |
165 |
125 |
125 |
125 |
102 |
102 |
99 |
4-~18 |
4-~18 |
4-~18 |
137 |
95 |
65 |
216 |
185 |
185 |
185 |
145 |
145 |
145 |
122 |
122 |
118 |
4-~18 |
4-~18 |
8-~18 |
145 |
97 |
80 |
241 |
200 |
200 |
200 |
160 |
160 |
160 |
133 |
133 |
132 |
8-~18 |
8-~18 |
8-~18 |
178 |
109 |
100 |
292 |
220 |
220 |
235 |
180 |
180 |
190 |
158 |
158 |
156 |
8-~18 |
8-~18 |
8-~18 |
232 |
152 |
125 |
330 |
250 |
250 |
270 |
210 |
210 |
220 |
184 |
184 |
184 |
8-~18 |
8-~18 |
8-~18 |
286 |
152 |
150 |
356 |
285 |
285 |
300 |
240 |
240 |
250 |
212 |
212 |
211 |
8-~18 |
8-~18 |
8-~18 |
318 |
160 |
200 |
495 |
340 |
340 |
360 |
295 |
295 |
310 |
268 |
268 |
274 |
8-~18 |
12-~18 |
12-~18 |
413 |
220 |
250 |
622 |
395 |
405 |
425 |
350 |
355 |
370 |
320 |
320 |
330 |
12-~18 |
12-~18 |
12-~18 |
502 |
250 |
300 |
698 |
445 |
460 |
485 |
400 |
410 |
430 |
370 |
370 |
389 |
12-~18 |
12-~18 |
12-~30 |
600 |
372 |
350 |
787 |
505 |
520 |
550 |
460 |
470 |
490 |
430 |
430 |
448 |
16-~22 |
16-~26 |
16-~33 |
526 |
314 |
400 |
914 |
565 |
580 |
620 |
515 |
525 |
550 |
482 |
482 |
503 |
16-~26 |
16-~30 |
16-~36 |
570 |
340 |
450 |
787 |
565 |
580 |
620 |
515 |
525 |
550 |
482 |
482 |
503 |
16-~26 |
16-~30 |
16-~36 |
677 |
415 |
|
| |
Main Technical Features |
|
| |
PN |
1.0MPa |
1.6MPa |
2.5MPa |
Shell Test |
1.5MPa |
2.4MPa |
3.75MPa |
Seal Test |
1.1MPa |
1.76MPa |
2.75MPa |
Suitable Temperature |
¡¶80oC |
Suitable Medium |
Water |
|